- Panels are cut on the 40 ft × 16 ft laser bed so a full canopy side is one piece, removing the split and weld that creates an oil-can and a corrosion path.
- Stiffening is designed in with returns and swages rather than added weight, because a flat 1.2 mm panel will drum at engine frequency.
- Coating is applied after seven-tank pretreatment in the same plant, so a panel does not travel between a fabricator and a coater.
Part requirements
A canopy panel is a large, thin, coated steel skin that has to stay flat, seal against weather and not drum under engine vibration. Getting it right is a stiffness and finishing problem before it is a cutting problem. The table below is the working specification; the customer drawing always takes precedence where the two differ.
Process route
Material. CRCA or pre-galvanised 1.2–2.0 mm. Control: Pre-galv needs edge protection.
Panel size. Up to 40 ft × 16 ft bed. Control: One-piece sides.
Flatness. Visual and straight-edge check. Control: Swage or return to control drumming.
Coating. Powder 60–80 µm, outdoor polyester. Control: Seven-tank pretreatment first.
What the drawing should state
Material grade and thickness, the tolerance on every functional feature, the finish and colour, masking requirements, weld size or symbol where relevant, the inspection level, and the packing method. Where a standard applies, name it and the revision. Three missing items on a drawing cause most quotation errors: material grade, finish specification and annual quantity.
Common failure modes
Panels fail in service at the fixings and the cut edges, not in the middle: a hole without a sealing washer, a laser-cut edge left with oxide under the powder, or a stiffener that creates a water trap. Drumming is a design failure that shows up as noise, not as a defect, and is cured with returns and swages rather than thicker steel.
What drives the cost
Area drives material and coating; panel count drives handling. A canopy made from six large one-piece panels costs less to fabricate, coat and seal than the same canopy made from fourteen smaller ones, because every joint is labour and every joint is a leak path.
Louvre free area decides the canopy
A genset needs air. A louvre panel looks like a simple set of blades, but its free area is what determines whether the set cools at rated load and how much back pressure the radiator fan sees. A louvre that is 45% free in a drawing note may be 32% free once the frame, bird mesh and blade angle are counted. The genset manufacturer's airflow requirement should be on the drawing, and the free area should be calculated, not assumed.
Sealing, access and the service technician
A canopy door is opened in the rain, by a technician with cold hands, often with the set running. Hinge side, latch type, door stiffness and the compression seal all decide whether the canopy stays weather-tight after a year of service. A door that needs two hands and a shoulder to close will be left ajar. Ganesh builds access doors with a formed return and a gasket groove so the seal has a defined compression, rather than relying on the latch to bend the panel flat.
Coating for the environment it will actually see
A canopy on a coastal site and a canopy under a shed are not the same specification. Pretreatment and powder choice should follow the corrosivity category rather than a colour code: a standard polyester powder over a seven-tank phosphate is a different proposition from a primer-plus-topcoat system for C4 or C5 exposure. Cutting the pretreatment to save cost is the fastest way to make a canopy that looks tired in two monsoons.
Design changes worth making
If a canopy is noisy, the answer is usually stiffness and sealing, not more insulation. If it leaks, the answer is usually the door and the fixing detail, not more sealant. If it rusts at the base, the answer is drainage and edge protection. None of these require a new material; they require the drawing to say how the panel is supported, sealed and drained.
What to send for a quotation
Send the genset model and rating, the canopy general arrangement, the acoustic target and measurement point, the airflow requirement, the base frame type, the coating specification, the annual quantity and the delivery location. A reference canopy or a photograph of the current unit is useful context, but the quotation should be built from a dimensioned drawing, not from a picture.
Quality evidence
Ganesh operates under ISO 9001:2015 and ISO 14001:2015, with an independent inspection function, material traceability to mill certificates and in-process inspection records. First article inspection reports and PPAP documentation are available where the programme requires them.
| Parameter | Typical value | Note |
|---|---|---|
| Material | CRCA or pre-galvanised 1.2–2.0 mm | Pre-galv needs edge protection |
| Panel size | Up to 40 ft × 16 ft bed | One-piece sides |
| Flatness | Visual and straight-edge check | Swage or return to control drumming |
| Coating | Powder 60–80 µm, outdoor polyester | Seven-tank pretreatment first |
Sources and review
- ISO 12944 corrosivity categories for outdoor steel · reviewed 2026-11-03
Part-level specification with route, control point and inspection evidence for genset canopy panel manufacturing.
Send the drawing and we will check the route